Your Benefits
- Benefit from a productivity boost and short downtimes thanks to the innovative diagnostic options
- Increase the level of automation and process transparency of your systems with IO-Link
- The reliable object pattern recognition without external signals or devices ensures a cost-effective and compact machine design
- Muting offers productivity and safety in human-material differentiation
- High availability: smart presence detection prevents unwanted switch-offs
- Easy commissioning and configuration without the need for software saves you time and money
Application
Performance level: Please select the required performance level (PLr) according to ISO 13849-1 and your risk
assessment.
Required performance level (PLr) according to ISO 13849-1: This standard uses a risk graph to determine the
required performance level. The parameters S, F and P are used to determine the magnitude of the risk.
The result of the procedure is a “required performance level” (PLr).
PL c
- Type 2
- SIL1
- SILCL1
- Category 2
- Type 4
- SIL3
- SILCL3
- Category 4
Cascading: Do you need a cascade of safety light curtains to protect from reaching over, reaching under
or standing behind the primary safety light curtain?
You can use cascading to connect up to 3 safety light curtain systems consisting of senders and receivers, e.g.
to provide reliable presence detection.
Scanning range: Which protective field width or scanning range is required in the application?
The protective field width is the dimension of the light path between sender and receiver. The maximum
protective field width is limited by the scanning range. Depending on the type of safety light curtain,
the available protective field widths are in the range of 0 m to 30 m.
Dynamic protective field width: Do the sender and receiver move toward or away from each other in normal
operation of the application?Can the protective field width change during normal operation?
The deTec safety light curtains automatically measure the protective field width when starting. The width is then
defined during operation.
If, however, it is necessary to be able to change the distance between the sender and receiver during operation
of your application, please contact to us.
Advantages
Intelligent safety light curtain for high productivity
Applications
Fields of applications
- Automotive and parts suppliers
- Machine tools industry
- Storage and conveyor technology
- Consumer goods industry
- Packaging industry
- Plastics and rubber industry
- Consumer goods industry
- Food and beverage industry
- Paint booths
Technical data overview
Safety level |
Type 2, PL c, SIL1 Type 4, PL e, SIL3 |
Resolution | 14 mm / 30 mm |
Scanning range | 2.5 m ... 30 m |
Protective field height | 300 mm ... 2,100 mm |
Enclosure rating |
IP65 IP67 IP66 IP69K |
Ambient operating temperature | –30 °C ... +55 °C |