M40S-70A503AA0, M40E-70A503AB0
Safety light curtains | M4000 Advanced Curtain
Receiver:
Details | Type:M40E-70A503AB0 | Part no.:1203222
Sender:
Details | Type:M40S-70A503AA0 | Part no.:1203250
Videos
Tutorial Safety light beam basics (1/8): What is the purpose of safety light beams?
Quality assurance of light beam systems
Features
System part |
Pair |
Resolution |
14 mm |
Scanning range |
10 m |
Protective field height |
1,800 mm |
Response time |
|
Without beam coding |
26 ms |
With beam coding |
56 ms |
|
Synchronization |
Optical synchronisation |
Safety-related parameters
Type |
Type 4 (IEC 61496-1) |
Safety integrity level |
SIL3 (IEC 61508) |
Category |
Category 4 (EN ISO 13849) |
Performance level |
PL e (EN ISO 13849) |
PFHD (mean probability of a dangerous failure per hour) |
28 * 10-9 (EN ISO 13849) |
TM (mission time) |
20 years (EN ISO 13849) |
Safe state in the event of a fault |
At least one OSSD is in the OFF state. |
Functions
| Functions | Delivery status |
---|
Restart interlock |
✔ |
External |
External device monitoring (EDM) |
✔ |
Deactivated |
Beam coding |
✔ |
Uncoded |
Configurable status output (ADO) |
✔ |
Contamination (OWS) |
Sender test |
✔ |
Deactivated |
Configurable scanning range |
✔ |
Low scanning range |
Safe SICK device communication via EFI |
✔ |
Differentiation between man and material (muting) |
✔ 1) |
1) The muting functions can only be used in combination with the UE403 muting switching amplifier or a suitable safety controller (e.g., Flexi Classic, Flexi Soft).
Functions - Functions in combination with UE403
Concurrence monitoring |
✔ |
Monitoring of total muting time |
✔ |
Sensor gap monitoring |
✔ |
Belt stop |
✔ |
Muting with override |
✔ |
Exit monitoring |
✔ |
End of muting by ESPE |
✔ |
Interfaces
System connection |
|
Connection type |
Hirschmann male connector M26, 12-pin |
Permitted cable length |
≤ 50 m 1) |
Permitted cross-section |
≥ 0 mm² |
|
Extension connection |
Female connector M12, 5-pin |
Configuration method |
Via software |
Configuration connection |
Female connector M8, 4-pin |
Display elements |
7-segment display, LEDs |
Status display |
LEDs |
1) Depending on load, power supply and wire cross-section. The technical specifications must be observed.
Electrical data
Protection class |
III (IEC 61140) |
Supply voltage VS |
24 V DC (19.2 V ... 28.8 V) |
Residual ripple |
≤ 10 % 1) |
Power consumption |
0.3 A: 0.8 A |
Output signal switching devices (OSSDs) |
|
Type of output |
2 PNP semiconductors, short-circuit protected, cross-circuit monitored 2) |
ON state, switching voltage HIGH |
24 V DC (VS – 2.25 V DC ... VS) |
OFF state, switching voltage LOW |
≤ 2 V DC |
Current-carrying capacity per OSSD |
≤ 500 mA |
|
Application diagnostic outputs |
|
Type of output |
PNP semiconductor, short-circuit protected 2) |
ON state, switching voltage HIGH |
24 V DC (VS – 4.2 V DC ... VS) |
OFF state, switching voltage LOW |
High resistance |
Current-carrying capacity per OSSD |
|
1) Within the limits of VS.
2) Applies to the voltage range between –30 V and +30 V.
Mechanical data
Housing cross-section |
52 mm x 55.5 mm |
Housing material |
Aluminum alloy ALMGSI 0.5 |
Surface treatment |
Powder coated |
Front screen material |
Polycarbonate, scratch-resistant coating |
Ambient data
Enclosure rating |
IP65 (EN 60529) |
Ambient operating temperature |
–30 °C ... +55 °C |
Storage temperature |
–30 °C ... +70 °C |
Air humidity |
15 % ... 95 %, Non-condensing |
Vibration resistance |
5 g, 10 Hz ... 55 Hz (IEC 60068-2-6) |
Shock resistance |
10 g, 16 ms (EN 60068-2-29) |
Other information