Safety light curtains C4000 Fusion Ex / Pair
Receiver:Details | Type:EXE-12C6602A020 | Part no.:1097731
Sender:Details | Type:EXS-12C6602A020 | Part no.:1097732
Please note: Sensor pre-assembled in explosion-proof enclosure including connecting cable (30 m, 12-wire, flying leads) and an enclosed connection cable for configuration and diagnostics. Depending on national regulations and requirements, a cable gland may have to be installed. The cable gland is available as an accessory.
Videos
Tutorial Safety light beam basics (1/8): What is the purpose of safety light beams?
Quality assurance of light beam systems
Features
-
Safety-related parametersApplication Explosive areas Ex-approvals ATEX for gas: II 2 G Ex db IIB T6
ATEX for dust: II 2 D Ex tb IIIC T56°C Db IP6X
NFPA 70/NEC 500 Class I, Div. 1, Groups C and D
NFPA 70/NEC 500 Class II, Div. 1, Groups E, F and G
NFPA 70/NEC 500 Class III, Div. 1
System part Pair Resolution 30 mm Protective field height 1,200 mm Scanning range 17.6 m Synchronization Optical synchronisation Type Type 4 (IEC 61496-1) Safety integrity level SIL3 (IEC 61508) Category Category 4 (EN ISO 13849) Performance level PL e (EN ISO 13849) PFHD (mean probability of a dangerous failure per hour) 15 x 10-9 (EN ISO 13849) TM (mission time) 20 years (EN ISO 13849) Safe state in the event of a fault At least one OSSD is in the OFF state. FunctionsFunctions Delivery status Protective operation ✔ Restart interlock ✔ External External device monitoring (EDM) ✔ Deactivated Beam coding ✔ Uncoded Configurable scanning range ✔ Reduced resolution ✔ Deactivated Fixed blanking ✔ Deactivated Floating blanking ✔ Deactivated Dynamic blanking for object pattern recognition ✔ Self-teaching dynamic blanking for goods detection ✔ Self-teaching dynamic blanking for pallet detection ✔ Multiple sampling ✔ 2x evaluation Direction monitoring ✔ Virtual photoelectric switches ✔ Sensor gap monitoring ✔ Sequence monitoring ✔ Object entry monitoring ✔ Detection of geometrically even objects ✔ Safe SICK device communication via EFI ✔ Functions in combination with UE402Bypass ✔ Operating mode switching ✔ InterfacesSystem connection Connecting cable (30 m) with flying leads, 12-wire Cable diameter 10 mm Conductor cross section 0.75 mm² Configuration connection Female connector M8, 4-pin Configuration method PC with CDS (Configuration and Diagnostic Software) Display elements 7-segment display Electrical dataProtection class III (IEC 61140) Supply voltage VS 24 V DC (19.2 V ... 28.8 V) 1) Residual ripple ≤ 10 % 2) Output signal switching devices (OSSDs) Type of output 2 PNP semiconductors, short-circuit protected, cross-circuit monitored 3) ON state, switching voltage HIGH 24 V DC (VS – 2.25 V DC ... VS) OFF state, switching voltage LOW ≤ 3.5 V DC Current-carrying capacity per OSSD ≤ 500 mA Application diagnostic output (ADO) Type of output PNP semiconductor, short-circuit protected 3) Output voltage HIGH (active) 24 V DC (VS – 4.2 V DC ... VS) Output voltage LOW (deactivated) High resistance Output current HIGH (active) ≤ 100 mA - 1) The external voltage supply must be capable of buffering brief mains voltage failures of 20 ms as specified in EN 60204-1. Suitable power supplies are available as accessories from SICK.
- 2) Within the limits of VS.
- 3) Applies to the voltage range between –30 V and +30 V.
Mechanical dataDimensions See dimensional drawing Housing cross-section 161.8 mm x 142.1 mm Housing material Aluminum cast/AlSi7Mg0.6 Ambient dataEnclosure rating IP65 (EN 60529)
IP66 (EN 60529)
Ambient operating temperature 0 °C ... +55 °C Storage temperature –25 °C ... +70 °C Air humidity 15 % ... 95 %, Non-condensing Vibration resistance 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Shock resistance 10 g, 16 ms (EN 60068-2-27) Other informationWave length 950 nm Type of light Near-infrared (NIR), invisible