Please note: Sensor pre-assembled in explosion-proof enclosure including connecting cable (30 m, 12-wire, flying leads) and an enclosed connection cable for configuration and diagnostics. Depending on national regulations and requirements, a cable gland may have to be installed. The cable gland is available as an accessory.
 
 

Videos

Tutorial Safety light beam basics (1/8): What is the purpose of safety light beams?
 
Safety light curtains with explosion-proof enclosure
 
 
Quality assurance of light beam systems
 
Features
Application      Explosive areas
Ex-approvals

     ATEX for gas: II 2 G Ex db IIB T6

     ATEX for dust: II 2 D Ex tb IIIC T56°C Db IP6X

     NFPA 70/NEC 500 Class I, Div. 1, Groups C and D

     NFPA 70/NEC 500 Class II, Div. 1, Groups E, F and G

     NFPA 70/NEC 500 Class III, Div. 1

System part      Pair
Resolution      30 mm
Protective field height      900 mm
Scanning range      16 m
Response time      12 ms
Synchronization      Optical synchronisation
Safety-related parameters
Type      Type 4 (IEC 61496-1)
Safety integrity level      SIL3 (IEC 61508)
Category      Category 4 (EN ISO 13849)
Performance level      PL e (EN ISO 13849)
PFHD (mean probability of a dangerous failure per hour)      15 x 10-9 (EN ISO 13849)
TM (mission time)      20 years (EN ISO 13849)
Safe state in the event of a fault      At least one OSSD is in the OFF state.
Functions
      Functions     Delivery status
Protective operation      ✔
Restart interlock      ✔      External
External device monitoring (EDM)      ✔      Deactivated
Beam coding      ✔      Uncoded
Configurable scanning range      ✔      0 m ... 5 m
Safe SICK device communication via EFI      ✔
Functions in combination with UE402
Bypass      ✔
Operating mode switching      ✔
PSDI mode      ✔
Interfaces
System connection      Connecting cable (30 m) with flying leads, 12-wire
Cable diameter      10 mm
Conductor cross section      0.75 mm²
Configuration connection      Female connector M8, 4-pin
Configuration method      PC with CDS (Configuration and Diagnostic Software)
Display elements      7-segment display
Electrical data
Protection class      III (IEC 61140)
Supply voltage VS      24 V DC (19.2 V ... 28.8 V) 1)
Residual ripple      ≤ 10 % 2)
Output signal switching devices (OSSDs)  
Type of output      2 PNP semiconductors, short-circuit protected, cross-circuit monitored 3)
ON state, switching voltage HIGH      24 V DC (VS – 2.25 V DC ... VS)
OFF state, switching voltage LOW      ≤ 3.5 V DC
Current-carrying capacity per OSSD      ≤ 500 mA
Application diagnostic output (ADO)  
Type of output      PNP semiconductor, short-circuit protected 3)
Output voltage HIGH (active)      24 V DC (VS – 4.2 V DC ... VS)
Output voltage LOW (deactivated)      High resistance
Output current HIGH (active)      ≤ 100 mA

1) The external voltage supply must be capable of buffering brief mains voltage failures of 20 ms as specified in EN 60204-1. Suitable power supplies are available as accessories from SICK.

2) Within the limits of VS.

3) Applies to the voltage range between –30 V and +30 V.

Mechanical data
Dimensions      See dimensional drawing
Housing cross-section      161.8 mm x 142.1 mm
Housing material      Aluminum cast/AlSi7Mg0.6
Weight      36.574 kg / 36.544 kg
Ambient data
Enclosure rating

     IP65 (EN 60529)

     IP66 (EN 60529)

Ambient operating temperature      0 °C ... +55 °C
Storage temperature      –25 °C ... +70 °C
Air humidity      15 % ... 95 %, Non-condensing
Vibration resistance      5 g, 10 Hz ... 55 Hz (EN 60068-2-6)
Shock resistance      10 g, 16 ms (EN 60068-2-27)
Other information
Wave length      950 nm
Type of light      Near-infrared (NIR), invisible