EXS-09C6403B020, EXE-09C6403B020
Safety light curtains | C4000 Advanced Ex
Safety light curtainsC4000 Advanced Ex / Pair
Receiver:
Details | Type:EXE-09C6403B020 | Part no.:1068400
Sender:
Details | Type:EXS-09C6403B020 | Part no.:1068401
Please note: Sensor pre-assembled in explosion-proof enclosure including connecting cable (30 m, 12-wire, flying leads) and an enclosed connection cable for configuration and diagnostics. Depending on national regulations and requirements, a cable gland may have to be installed. The cable gland is available as an accessory.
Videos
Tutorial Safety light beam basics (1/8): What is the purpose of safety light beams?
Safety light curtains with explosion-proof enclosure
Quality assurance of light beam systems
Features
Application |
Explosive areas |
Ex-approvals |
ATEX for gas: II 2 G Ex db IIB T6
ATEX for dust: II 2 D Ex tb IIIC T56°C Db IP6X
NFPA 70/NEC 500 Class I, Div. 1, Groups C and D
NFPA 70/NEC 500 Class II, Div. 1, Groups E, F and G
NFPA 70/NEC 500 Class III, Div. 1
|
System part |
Pair |
Resolution |
30 mm |
Protective field height |
900 mm |
Scanning range |
16 m |
Response time |
12 ms |
Synchronization |
Optical synchronisation |
Safety-related parameters
Type |
Type 4 (IEC 61496-1) |
Safety integrity level |
SIL3 (IEC 61508) |
Category |
Category 4 (EN ISO 13849) |
Performance level |
PL e (EN ISO 13849) |
PFHD (mean probability of a dangerous failure per hour) |
15 x 10-9 (EN ISO 13849) |
TM (mission time) |
20 years (EN ISO 13849) |
Safe state in the event of a fault |
At least one OSSD is in the OFF state. |
Functions
| Functions | Delivery status |
---|
Protective operation |
✔ |
Restart interlock |
✔ |
External |
External device monitoring (EDM) |
✔ |
Deactivated |
Beam coding |
✔ |
Uncoded |
Configurable scanning range |
✔ |
0 m ... 5 m |
Safe SICK device communication via EFI |
✔ |
Functions in combination with UE402
Bypass |
✔ |
Operating mode switching |
✔ |
PSDI mode |
✔ |
Interfaces
System connection |
Connecting cable (30 m) with flying leads, 12-wire |
Cable diameter |
10 mm |
Conductor cross section |
0.75 mm² |
|
Configuration connection |
Female connector M8, 4-pin |
Configuration method |
PC with CDS (Configuration and Diagnostic Software) |
Display elements |
7-segment display |
Electrical data
Protection class |
III (IEC 61140) |
Supply voltage VS |
24 V DC (19.2 V ... 28.8 V) 1) |
Residual ripple |
≤ 10 % 2) |
Output signal switching devices (OSSDs) |
|
Type of output |
2 PNP semiconductors, short-circuit protected, cross-circuit monitored 3) |
ON state, switching voltage HIGH |
24 V DC (VS – 2.25 V DC ... VS) |
OFF state, switching voltage LOW |
≤ 3.5 V DC |
Current-carrying capacity per OSSD |
≤ 500 mA |
|
Application diagnostic output (ADO) |
|
Type of output |
PNP semiconductor, short-circuit protected 3) |
Output voltage HIGH (active) |
24 V DC (VS – 4.2 V DC ... VS) |
Output voltage LOW (deactivated) |
High resistance |
Output current HIGH (active) |
≤ 100 mA |
|
1) The external voltage supply must be capable of buffering brief mains voltage failures of 20 ms as specified in EN 60204-1. Suitable power supplies are available as accessories from SICK.
2) Within the limits of VS.
3) Applies to the voltage range between –30 V and +30 V.
Mechanical data
Dimensions |
See dimensional drawing |
Housing cross-section |
161.8 mm x 142.1 mm |
Housing material |
Aluminum cast/AlSi7Mg0.6 |
Weight |
36.574 kg / 36.544 kg |
Ambient data
Enclosure rating |
IP65 (EN 60529)
IP66 (EN 60529)
|
Ambient operating temperature |
0 °C ... +55 °C |
Storage temperature |
–25 °C ... +70 °C |
Air humidity |
15 % ... 95 %, Non-condensing |
Vibration resistance |
5 g, 10 Hz ... 55 Hz (EN 60068-2-6) |
Shock resistance |
10 g, 16 ms (EN 60068-2-27) |
Other information
Wave length |
950 nm |
Type of light |
Near-infrared (NIR), invisible |