C40S-S146, C40E-S146
Safety light curtains | C4000 Fusion ATEX II 3G/3D / Pair
Receiver:
Details | Type:C40E-S146 | Part no.:1081932
Sender:
Details | Type:C40S-S146 | Part no.:1081931
Videos
Quality assurance of light beam systems
Tutorial Safety light beam basics (1/8): What is the purpose of safety light beams?
Features
Application |
Explosive areas |
Ex-approvals |
ATEX for gas: II 3G Ex nA op is IIC T4 Gc X
ATEX for dust: II 3D Ex tc IIIC T135°C Dc
|
System part |
Pair |
Resolution |
20 mm |
Protective field height |
900 mm |
Scanning range |
21 m |
Synchronization |
Optical synchronisation |
Integrated laser alignment aid |
✔ |
Safety-related parameters
Type |
Type 4 (IEC 61496-1) |
Safety integrity level |
SIL3 (IEC 61508) |
Category |
Category 4 (EN ISO 13849) |
Performance level |
PL e (EN ISO 13849) |
PFHD (mean probability of a dangerous failure per hour) |
15 x 10-9 (EN ISO 13849) |
TM (mission time) |
20 years (EN ISO 13849) |
Safe state in the event of a fault |
At least one OSSD is in the OFF state. |
Functions
| Functions | Delivery status |
---|
Protective operation |
✔ |
Restart interlock |
✔ |
Internal |
External device monitoring (EDM) |
✔ |
Deactivated |
Beam coding |
✔ |
Code 1 |
Configurable scanning range |
✔ |
Reduced resolution |
✔ |
Deactivated |
Fixed blanking |
✔ |
Deactivated |
Floating blanking |
✔ |
Deactivated |
Dynamic blanking for object pattern recognition |
✔ |
Self-teaching dynamic blanking for goods detection |
✔ |
Self-teaching dynamic blanking for pallet detection |
✔ |
Multiple sampling |
✔ |
2x evaluation |
Direction monitoring |
✔ |
Virtual photoelectric switches |
✔ |
Sensor gap monitoring |
✔ |
Sequence monitoring |
✔ |
Object entry monitoring |
✔ |
Detection of geometrically even objects |
✔ |
Safe SICK device communication via EFI |
✔ |
Functions in combination with UE402
Bypass |
✔ |
Operating mode switching |
✔ |
Interfaces
System connection |
Hirschmann male connector M26, 12-pin |
Direction of cable connection |
Straight |
Conductor cross section |
0.75 mm² |
Permitted cable length |
50 m 1) |
|
Configuration connection |
Female connector M8, 4-pin |
Configuration method |
PC with CDS (Configuration and Diagnostic Software) |
Display elements |
7-segment display |
1) Depending on load, power supply and wire cross-section. The technical specifications must be observed.
Electrical data
Protection class |
III (IEC 61140) |
Supply voltage VS |
24 V DC (19.2 V ... 28.8 V) 1) |
Residual ripple |
≤ 10 % 2) |
Output signal switching devices (OSSDs) |
|
Type of output |
2 PNP semiconductors, short-circuit protected, cross-circuit monitored 3) |
ON state, switching voltage HIGH |
24 V DC (VS – 2.25 V DC ... VS) |
OFF state, switching voltage LOW |
≤ 2 V DC |
Current-carrying capacity per OSSD |
≤ 500 mA |
|
Application diagnostic output (ADO) |
|
Type of output |
PNP semiconductor, short-circuit protected 3) |
Output voltage HIGH (active) |
24 V DC (VS – 4.2 V DC ... VS) |
Output voltage LOW (deactivated) |
High resistance |
Output current HIGH (active) |
≤ 100 mA |
1) The external voltage supply must be capable of buffering brief mains voltage failures of 20 ms as specified in EN 60204-1. Suitable power supplies are available as accessories from SICK.
2) Within the limits of VS.
3) Applies to the voltage range between –30 V and +30 V.
Mechanical data
Dimensions |
See dimensional drawing |
Housing cross-section |
48 mm x 40 mm |
Housing material |
Aluminum extruded profile |
Ambient data
Enclosure rating |
IP65 (EN 60529) |
Ambient operating temperature |
0 °C ... +55 °C |
Storage temperature |
–25 °C ... +70 °C |
Air humidity |
15 % ... 95 %, Non-condensing |
Vibration resistance |
5 g, 10 Hz ... 55 Hz (EN 60068-2-6) |
Shock resistance |
10 g, 16 ms (EN 60068-2-27) |
Other information
Wave length |
950 nm |
Type of light |
Near-infrared (NIR), invisible |
Integrated laser alignment aid |
✔ |
Laser class |
1 |
Wave length |
650 nm |
Type of light |
Visible red light |
|