Videos
Application | Explosive areas |
Ex-approvals |
ATEX for gas: II 3G Ex nA op is IIC T4 Gc X ATEX for dust: II 3D Ex tc IIIC T135°C Dc |
System part | Pair |
Resolution | 14 mm |
Scanning range | 10 m |
Protective field height | 1,800 mm |
Response time |
26 ms (Uncoded) 56 ms (code 1 or code 2) |
Synchronization | Optical synchronisation |
Type | Type 4 (IEC 61496-1) |
Safety integrity level | SIL3 (IEC 61508) |
Category | Category 4 (EN ISO 13849) |
Performance level | PL e (EN ISO 13849) |
PFHD (mean probability of a dangerous failure per hour) | 15 x 10-9 (EN ISO 13849) |
TM (mission time) | 20 years (EN ISO 13849) |
Safe state in the event of a fault | At least one OSSD is in the OFF state. |
Functions | Delivery status | |
---|---|---|
Protective operation | ✔ | |
Restart interlock | ✔ | External |
External device monitoring (EDM) | ✔ | Deactivated |
Beam coding | ✔ | Uncoded |
Configurable scanning range | ✔ | |
Reduced resolution | ✔ | Deactivated |
Fixed blanking | ✔ | Deactivated |
Floating blanking | ✔ | Deactivated |
Safe SICK device communication via EFI | ✔ |
Bypass | ✔ |
Operating mode switching | ✔ |
PSDI mode | ✔ |
|
|||||||||
Configuration connection | Female connector M8, 4-pin | ||||||||
Configuration method | PC with CDS (Configuration and Diagnostic Software) | ||||||||
Display elements | 7-segment display |
1) Depending on load, power supply and wire cross-section. The technical specifications must be observed.
Protection class | III (IEC 61140) | ||||||||||
Supply voltage VS | 24 V DC (19.2 V ... 28.8 V) 1) | ||||||||||
Residual ripple | ≤ 10 % 2) | ||||||||||
|
|||||||||||
|
1) The external voltage supply must be capable of buffering brief mains voltage failures of 20 ms as specified in EN 60204-1. Suitable power supplies are available as accessories from SICK.
2) Within the limits of VS.
3) Applies to the voltage range between –30 V and +30 V.
Dimensions | See dimensional drawing |
Housing cross-section | 48 mm x 40 mm |
Housing material | Aluminum extruded profile |
Enclosure rating | IP65 (EN 60529) |
Ambient operating temperature | 0 °C ... +55 °C |
Storage temperature | –25 °C ... +70 °C |
Air humidity | 15 % ... 95 %, Non-condensing |
Vibration resistance | 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) |
Shock resistance | 10 g, 16 ms (EN 60068-2-27) |
Wave length | 950 nm |
Type of light | Near-infrared (NIR), invisible |