C2MT-01224BBC03BB0 | Part no.: 1207942

Safety light curtains | miniTwin

C2MT-01214BBC03BB0

 

 

Type: C2MT-01224BBC03BB0 | Part no.:1207942
Please note: This article includes 1 twin stick. Please order 2 for a functioning miniTwin2 system. Important notes: 1.) Concerns installation as a spare part: This type 2 device may be used as per section 1, paragraph (2a) of Machinery Directive 2006/42/EC within the EU as a spare part for identical PL d/SIL2 devices only if the machine was put on the market before 10/5/2015. Keep this note with your machine documentation. If the machine is resold, this note must be passed on to the next buyer. 2.) Concerns installation in new machines: Due to the amendment to the EN/IEC 61496-1 standard, this type 2 device may only be installed on new machines up to PLc/SIL1 as of 5/10/2015.

 

Videos
 
miniTwin4: The smallest safety light curtain from SICK
 
Quality assurance of light beam systems
 
Tutorial Safety light beam basics (1/8): What is the purpose of safety light beams?
 
Features
System part      1 Twin-Stick
Usage

     miniTwin4 as a standalone device

Mounting system type      O-fix bracket
Resolution      24 mm
Scanning range  
Minimum      0 m ... 6 m
Typical      0 m ... 8 m
Protective field height      120 mm
Response time      ≤ 13 ms 1)
Synchronization      Optical, without separate synchronization
Items supplied

     Twin stick

     System plug

     O-Fix bracket, 2 pieces each

     Test rod with diameter corresponding to the resolution of the safety light curtain

     Safety instruction

     Mounting instructions

     Operating instructions for download

1) Standalone devices, no cascaded systems. Other response times can be found in the operating instructions.

Safety-related parameters
Type      Type 2 (IEC 61496-1)
Safety integrity level      SIL1 (IEC 61508)
Category      Category 2 (EN ISO 13849)
Test rate (internal test)      58 /s
Maximum demand rate      ≤ 34 min⁻¹ (EN ISO 13849) 1)
Performance level      PL c (EN ISO 13849), Pay attention to optical characteristics! 2)
PFHD (mean probability of a dangerous failure per hour)      Standalone system: 2.4 x 10-8 (EN ISO 13849)
TM (mission time)      20 years (EN ISO 13849)
Safe state in the event of a fault      At least one OSSD is in the OFF state.

1) Between two requirements on a safety-related response of the device, at least 100 internal or external tests must be carried out.

2) The performance level does not include any specific requirements regarding aspects such as optical performance features. For more information, see page xx.

Functions
      Functions     Delivery status
Restart interlock      ✔      Deactivated
External device monitoring (EDM)      ✔      Deactivated
Beam coding      Automatic
Interfaces
System connection      Male connector M12, 5-pin
Length of cable      160 mm
Conductor cross section      0.34 mm²
Permitted cable length      ≤ 20 m 1)
Configuration method      Hard wired
Display elements      LEDs

1) Depending on load, power supply and wire cross-section. The technical specifications must be observed.

Electrical data
Protection class      III (EN 61140)
Supply voltage VS      24 V DC (19.2 V DC ... 28.8 V DC)
Ripple      ≤ 10 % 1)
Power consumption      ≤ 3 A 2)
Output signal switching devices (OSSDs)  
Type of output      PNP semiconductors, short-circuit protected, cross-circuit monitored 3)
ON state, switching voltage HIGH      24 V DC (VS – 2.25 V DC ... VS)
OFF state, switching voltage LOW      ≤ 2 V DC
Current-carrying capacity per OSSD      ≤ 300 mA

1) Within the limits of VS.

2) Maximum power consumption of a host/guest/guest system with 1,200 mm protective field height and a resolution of 14 mm.

3) Applies to the voltage range between –30 V and +30 V.

Mechanical data
Housing cross-section (incl. system connection)      15 mm x 32 mm
Housing material      Aluminum alloy ALMGSI 0.5
Weight      50 g
Ambient data
Enclosure rating      IP65 (EN 60529)
Ambient operating temperature      –20 °C ... +55 °C
Storage temperature      –25 °C ... +70 °C
Air humidity      15 % ... 95 %, Non-condensing
Vibration resistance      5 g, 10 Hz ... 55 Hz (EN 60068-2-6)
Shock resistance      10 g, 16 ms (EN 60068-2-27)
Other information
Wave length      850 nm